Product Introduction
10GPON Optical Power Meter is mainly for the installation, test and maintenance of FTTH fiber access network. It not only has all the functions of general optical power meter, but also has the power measurement function of 1577nm and 1490nm wavelength downlink designed for 10GEPON/XGPON. So that the installation and maintenance personnel can truly master the power value of a single wavelength optical signal on the line, and can accurately judge whether the optical power value reaches the standard. In addition, the 10GPON Optical Power Meter also has the function of 10MW red light source, which is frequently used in daily use, and RJ45 sequence test function. Multifunctional integration, make the daily test need to carry more simple instrument. 18650 large capacity (2200mAH) lithium battery power supply, long life, environmental protection and durable.
Features
◇ 10GPON optical power and conventional optical power in one, the working mode is optional
◇ Self Calibration
◇ Set the Auto Off
◇ Wavelength Memory function after turn off the tester
◇ High Accuracy, high ,High sensitivity, high linearity
◇ RJ45 Cable sequence test function
◇ Stable VFL Output
◇ USB Charge port
◇ FC,SC Connector
◇ 18650Li-ion Battery
◇ Lower power consumption design, long standby time
◇ Replaceable ceramic sleeve for red light source
◇ Rubber Out shell, increased the protective properties for field work
Specification
10GPON Optical Power Meter | ||
Scope of application | 10GEPON/XGPON | |
Wavelengths(nm) | 1490nm/1577nm | |
Isolation | >35dB | |
Measurement Range(dBm) | -40~ +10dBm | |
Display Resolution(dBm) | 0.01 | |
Display Units | mW/uW/nW/ dBm/dB | |
Uncertainty(dB) | ±0.5dB (2%) @25℃ | |
Optical Power Meter | ||
Measurement Range(dBm) | -70~ +10 | -50~ +26 |
Detector Type | InGaAs | |
Application | Single, multi - mode optical fiber | |
Calibrated Wavelengths(nm) | 850/980/1300/1310/1490/1550/1625nm | |
Resolving Power(dBm) | 0.01 | |
Display Units | mW/uW/nW/ dBm/dB | |
Uncertainty(dB) | ±0.25dB (2%) @25℃(±0.5 dB @850nm) | |
VFL | ||
luminescent device | FP-LD | |
Output Power | 1mw/10mw/20mw/30mw(Optional) | |
Wavelength(nm) | 650 | |
Typical output optical power(mW) | >10 | |
Mode | CW/1Hz/2Hz | |
Others | ||
Power Supply | 18650 Li-con battery | |
Automatic Shutdown Time | 10min | |
Continuous Working Time |
>200 hours (Single optical power meter working) ≥ 50 hours (10mW VFL and OPM work at the same time) |
|
Connector | 2.5mm Universal joint | |
Working Temperature(℃) | -10~+45 | |
Storage Temperature(℃) | -20~+65 | |
Weight(g) | 250(Battery included) |