Location: Home > Prouduct > OTDR >

OTDR TM291 Optical fiber tester

 

Standard Function: OTDR/Optical Power Meter/ Optical Light Source/ Visual Fault Locator/ Optic Loss/ Light Optional Function: Line Order/ Tracing Test

Inquiry Now
Ordering Details
TM291D 1310/1550nm, 24/22dB Touching screen
TM291D 1310/1550nm, 26/24dB Touching screen,
TM291SF-15(with filter) 1550nm, 20dB Touching screen, support active test
TM291SF-16(with filter) 1610nm, 20dB Touching screen, support active test
 
Function

Standard Function OTDR, OPM, OLS, VFL, Optic Loss,Light
Optional Function Line Order, Tracing Test

Functions

1. OTDR:  0-60km
2. Optical Power Meter : -70~+10dbm or -50~+26dbm
3. Visual Fault Locator : >=10mw
4. Optical Light Source : 1310/1550nm ,>-5dBm
5. Optic Loss
6. Line Order (Optional)
7. Tracing Test (Optional): Can track the direction of the found line.
8. LED lighting function, dark environment construction is more convenient
 
 

Features

1. Measurement distance: 60km
2. Touching screen
3. Test record can be saved as so format
4. Standard Function: OTDR/Optical Power Meter/ Optical Light Source/ Visual Fault Locator/
Optic Loss/ Light
Optional Function: Line Order/ Tracing Test
5. Editable file name and lineNo.
6. Support upgrade
7. Quick boot, it takes only 2 seconds to test
 
Specifications

OTDR
Wavelength(nm) 1310/1550nm 1310/1550nm 1550nm 1610nm
Dynamic Range 24/22dB 26/24dB 20dB 20dB
Active Test no no yes yes
Measurement Distance 0-60 km
Type of Fiber 9/125um SM
Type of Connectors FC/PC/; SC/PC (FC/APC SC/APC--Optional)
Peak Value of laser >=30mW
Unit Meter/ inch/ mile
Dead Zone of Reflection 2m
Dead Zone of
attenuation Event
12m
Accuracy Distance 
(Reflection Event)
About ±(1m+2 *10(-4)* distance)
Storage of records 200 groups
Visual Fault locator(VFL)
Wavelength (nm) 650nm
Output power >=10mW
Mode CW,1Hz,2Hz
Fiber type SM
Optical Power Meter
Measurement range dBm -70~+10 dBm -50~+26 dBm
Wavelength range(nm) 800~1650
Calibrated wavelength 850、1300、1310、1490、1550、1625
Detector InGaAs
Accuracy <±3% (-10dBm、22℃)
Resolution Linearity:0.1%,Non-linearity:0.01dBm
Connector Changeable FC/PC SC/PC ( ST as Optional)
Optical Light Source
Emitter FP-LD
wavelength (nm) 1310/1550nm
Connector FC/PC(SC/ST as optional)
Output power ≥-5dBm
Output stability(dBm) ±0.04@20℃@15min
Modulation CW/270Hz/1KHz/2KHz
Fiber type SM
Optic Loss
Connector FC/ SC
Test Range 0-30dB
Accuracy 10%
Others
LCD 3.97inch,800*480pixels, IPS screen
Battery 7.4V/4400mAH Lithium-ion battery, >5000 tests
Temperature Work temperature: -5 ~ 50 ° C, storage temperature: -10 ~ 60 ° C
Humidity 0~85%(Non-condensing)
Dimensions(mm) 180×100×45
Weight(g) 480
Standard Function OTDR, OPM, OLS, VFL, Optic Loss,Light
Optional Function Line Order, Tracing Test